HOOPS Exchange 2026.8.0
#######################

Technology Updates
==================

.. note:: Upcoming Changes to Linux Binaries

   HOOPS Exchange has upcoming changes related to how we distribute on GNU/Linux.
   The Linux binary will migrate from a single dynamic library to multiple dynamic libraries.

   This aims to improve usability, flexibility and standard behaviour across operating systems and platforms.

Format Updates
--------------

================== ====================
*Format*           *Updated Version*
================== ====================
Parasolid          39
================== ====================

See :doc:`/start/supported-formats` for the list of all supported formats.


Third-Party Library Updates
---------------------------

The following third-party libraries have been updated:

================== ====================
*Library*          *New Version*
================== ====================
Nlohmann's JSON    3.11.3
================== ====================

For more information about package content, see :doc:`/start/acknowledgments` and :doc:`/distributing`.


Platform Changes
----------------

iOS binaries are now distributed as shared libraries `libA3DLIBS.26.8.0.dylib`, `libA3DLIBS.dylib` (the symbolic link pointing to `libA3DLIBS.26.8.0.dylib`) and `hepb.dylib`.
Please refer to :doc:`distributing` for more information about the iOS package content and usage.

Windows binaries no longer include TFUGEOM.dll. This legacy component has been removed from the package content.

Software Bill of Materials (SBOM):
-----------------------------------------
Versioned SBOM artifacts are now available on demand in both SPDX 2.3 and CycloneDX 1.6 formats for all customer packages (except the ones under Related Technologies). This enhancement supports transparency, security review, and compliance workflows for our partners.
A beta-version of the SBOM can be requested from this release onwards in order for partners to test integration into their CI/CD systems. In upcoming releases these SBOM files will be made available in the customer package directly. 
Please use the `Support Portal <https://partner.support.techsoft3d.com/helpcenter/sdk/portal/7>`__ to raise an info request to get the SBOMs needed.


Sample Build System
-------------------

Since HOOPS Exchange 2026.6.0, the Linux and macOS packages no longer include standalone Makefiles for the samples.
Build the samples with CMake instead.

See :doc:`/release_notes/2026.6.0` and :doc:`/examples/build`.


New Features
============

JT Export Conforms to the JT Specification
------------------------------------------

As of HOOPS Exchange 2026.8.0, HOOPS Exchange exports fully compliant JT files. 

JT files exported from HOOPS Exchange now meet stricter, safer and more reliable requirements, such as those of popular JT readers, including Siemens products starting with 2612 releases, and applications built on JT Open Toolkit 12.2 and later.

While JT files exported with earlier versions of HOOPS Exchange will still open in applications with less strict requirements, they may fail to open in applications implementing these stricter requirements.

To help you identify these files, the JT reader will report a warning in the log upon loading.
A dedicated utility to update existing JT files to these new stricter requirements is planned for a future release.
This utility will correct only the required data and leave everything else unchanged.
While we complete and release this utility, you can re-export any affected files to JT with HOOPS Exchange 2026.8.0 or later, for example using the :doc:`ImportExport sample </examples/import_export>`.
Re-exporting the JT files has the potential to change the file content, as the JT writer improves throughout releases.

See :ref:`jt_wr_conformance`.

JT Symbolic Thread Import Behavior Change
-----------------------------------------

JT files can encode a threaded feature as a "Symbolic Thread" PMI entity: a lightweight point or polyline standing in for the real thread geometry.
This entity used to be imported as a generic PMI markup.
It is now imported as a point (:c:enum:`kA3DTypeRiPointSet`) or polywire (:c:enum:`kA3DTypeRiPolyWire`) representation item added to the part instead, matching how NX and JT2Go display it.

This geometry is now imported even when PMI reading is disabled (:c:member:`A3DRWParamsGeneralData.m_bReadPmis` set to `A3D_FALSE`), since the thread data can only be recovered by parsing the PMI stream.
As a result, code that iterates a part's representation items may now see additional point or polywire items for JT files containing symbolic threads.

See :doc:`/start/format/jt_reader`.

Creo Embedded Components Support
--------------------------------

The Creo reader now supports embedded components, which are parts and sub-assemblies stored inside their parent assembly file.
These embedded components include Creo Inseparable Assemblies, which are self-contained, embedded assemblies.
Previously, Embedded Components were not imported and loading a file with this data could return a ``A3D_LOAD_MISSING_COMPONENTS`` error.
Embedded Components are now imported as regular product occurrences, hence the assembly tree of Creo models containing Embedded Components may contain additional occurrences.

See :ref:`creo_embedded`.

3DXML Capture Visibility Resolution Change
------------------------------------------

As of HOOPS Exchange 2026.8.0, capture visibility is resolved per piece of geometry rather than per product occurrence, and only for the pieces that differ from what's visible by default, matching the 3DXML Player more closely.

A capture view can only show geometry that was loaded.
If :c:member:`A3DRWParamsGeneralData.m_bReadHiddenObjects` or :c:member:`A3DRWParamsGeneralData.m_bReadConstructionAndReferences` is set to `A3D_FALSE`, capture views revealing hidden or construction geometry may no longer match the 3DXML Player.

See :doc:`/start/format/catia_v6_reader`.

Physical Properties Computation Behavior Change
-------------------------------------------------

:func:`A3DComputeModelFilePhysicalProperties` does not modify the input geometry anymore.

Previously, when :member:`A3DPhysicalPropertiesData.m_bUseGeometryOnRiBRep` was set to ``A3D_TRUE``, computing physical properties from B-Rep data automatically split faces at seams and computed UV parameterization on the input B-Rep, as if :func:`A3DAdaptAndReplaceAllBrepInModelFile` had been called with :member:`A3DCopyAndAdaptBrepModelData.m_bSplitFaces` and :member:`A3DCopyAndAdaptBrepModelData.m_bForceComputeUV` set to `A3D_TRUE`.
This happened for both :func:`A3DComputeModelFilePhysicalProperties` and :func:`A3DComputePhysicalProperties`.

As of 2026.8.0, the computation runs on an internal copy instead, and the input geometry is left untouched.

If your workflow relied on the above described implicit modification of the geometry, call :func:`A3DAdaptAndReplaceAllBrepInModelFile` explicitly with the same options to continue obtaining the same result.

See :doc:`/guide/geometry/convert_brep_to_nurbs`.

CATIA V5: names of the geometrical sets without user-defined name
-----------------------------------------------------------------

HOOPS Exchange names the geometrical sets that carry no user-defined name after their internal CATIA V5 type, for instance ``Open_body.1``, whereas CATIA V5 displays ``Geometrical Set.1``, ``Ordered Geometrical Set.1``, ``External References``, or ``Isolated External References``.
The new reading option :c:member:`A3DRWParamsCatiaV5Data.m_eGenericNames`, set to :c:enumerator:`kA3DCatiaV5GenericNamesDisplayed`, returns the labels displayed by CATIA V5 in the model tree and in the feature tree.
The default value keeps the historical names.

See :doc:`/start/format/catia_v5_reader` for CATIA V5 assembly-tree naming, and :c:struct:`A3DRWParamsCatiaV5Data` for the other CATIA V5-specific read options.

Revit Loading Performance Improvement
-------------------------------------

Improved loading performance of large Revit files when views are read.
The performance gains increase with the number of 3D views and elements in the model:
large models with many 3D views can load more than ten times faster, while the loading times of small files are mostly unchanged.

See :doc:`/start/format/revit_reader`.

DWF Model Tree Names and Order
------------------------------

As of HOOPS Exchange 2026.8.0, the model tree of DWF and DWFX files is closer to the tree displayed by Autodesk viewers.

* HOOPS Exchange matches each product occurrence with its object in the XML content of the DWF file more reliably.
  Product occurrences take the label of that object as their name, and its properties as attributes.
  Fewer product occurrences keep a numeric name or receive the name of another object.
* Sibling product occurrences are sorted by their node number in the DWF graphics.
* Unnamed product occurrences without child occurrences are removed when they are directly below the root product occurrence.

As a result, code that walks the assembly tree of a DWF file, or that finds product occurrences by name, may see different names, a different order of siblings, and fewer product occurrences.

See :ref:`DWF assembly section <dwf_assembly>`.


API Changes
===========

* New experimental API for tessellation computation in C# wrapper: :c:func:`A3DAsmModelFileComputeTessellation2`, :c:func:`A3DRiRepresentationItemComputeTessellation2`, along with a new sample in packaging to demonstrate their use.
* New enumeration :c:enum:`A3DECatiaV5GenericNames` and new member :c:member:`A3DRWParamsCatiaV5Data.m_eGenericNames`, to choose the names of the CATIA V5 geometrical sets that carry no user-defined name.

Documentation Changes
=====================

The :doc:`/start/format/gltf_writer` page now has a :ref:`Wireframe <gltf_wt_wireframe>` section clarifying the scope of :c:member:`A3DRWParamsExportGltfData.m_bExportEdgeWires`.

The :doc:`/start/format/autodesk_dwf_reader` page has a :ref:`Model Tree Names and Order <dwf_assembly>` section that describes how HOOPS Exchange names and orders DWF product occurrences.

Deprecations
============

* :c:func:`A3DMiscPointerFromIndexGet` is deprecated. It will be renamed ``A3DGlobalGetEntity`` in the 2027.1.0 release.

Fixed Bugs
==========

.. csv-table::
   :header: "Issue", "Description"

   SDHE-23916,"Fixed unexpected behavior when importing multiple IFC files in a row"
   SDHE-23831,"Fixed incorrect UTF8 text in PMI of JT files"
   SDHE-23808,"Fixed missing triangles on some faces with grid-aligned tessellation"
   SDHE-23780,"Fixed unexpected behavior in experimental tessellation at low angle tolerance"
   SDHE-23723,"Added a CATIA V5 option to keep geometrical set names as shown in CATIA"
   SDHE-23649,"Fixed incorrect visibility of hidden bodies in 3DXML views"
   SDHE-23593,"Fixed symbolic thread curves incorrectly imported as PMI in JT files"
   SDHE-23518,"Fixed incorrect pattern instances in some SolidWorks configurations"
   SDHE-23368,"Fixed child parts wrongly excluded in nested Creo simplified representations"
   SDHE-23328,"Fixed incorrect step value of SolidWorks equal-spacing circular patterns"
   SDHE-23279,"Fixed missing semantic feature control frame values in STEP PMI export"
   SDHE-22911,"Fixed missing meshes when exporting CATIA V5 scan bodies to Parasolid"
   SDHE-22903,"Fixed wrong parts imported in SolidWorks assemblies"
   SDHE-22892,"Fixed incorrect placement of Solid Edge adjustable components"
   SDHE-22841,"Fixed hidden SolidWorks helix curves imported when hidden objects are off"
   SDHE-22815,"Fixed DGN extrusion solids imported as open shells"
   SDHE-22814,"Fixed DGN extrusion solids imported as open shells"
   SDHE-22632,"Fixed missing textures when importing some Inventor files"
   SDHE-22540,"Fixed incorrect tessellation of some periodic surfaces in Parasolid files"
   SDHE-22440,"Fixed part deformation when exporting Inventor files to ACIS with Simplify"
   SDHE-22379,"Fixed missing spheres when importing IGES files"
   SDHE-22079,"Fixed loading of some STEP AP242 files exported from Inventor"
   SDHE-21967,"Fixed incorrect placement of parts when importing Solid Edge files"
   SDHE-20007,"Fixed DWF model tree nodes showing numeric IDs instead of part names"
   SDHE-19894,"Fixed incorrect model tree structure when importing DWF files"
   SDHP-3115,"Fixed incorrect DL180pdfl.dll file name in the Distributing page"